Jumo 705030 mTRON T - Digital Input/Output Module Opera Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Jumo 705030 mTRON T - Digital Input/Output Module Opera. JUMO 705030 mTRON T - Digital Input/Output Module Operating Manual User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 50
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
JUMO mTRON T
Measuring, Control, and Automation System
Digital Input/Output Module 12-Channel
B 705030.0
Operating Manual
2014-01-20/00575632
Vue de la page 0
1 2 3 4 5 6 ... 49 50

Résumé du contenu

Page 1 - JUMO mTRON T

JUMO mTRON TMeasuring, Control, and Automation SystemDigital Input/Output Module 12-ChannelB 705030.0Operating Manual2014-01-20/00575632

Page 2

1 Introduction101.3.4 DisposalDisposing of the deviceDisposing of the packaging materialThe entire packaging material (cardboard packaging, inserts, p

Page 3 - Contents

111 Introduction1.4 Identifying the Device Version1.4.1 NameplatesPositionThe nameplate (B) is affixed to the module case.An additional nameplate with

Page 4

1 Introduction12Fabrication no. (F-Nr)Among other things, the fabrication number contains the date of production (year/week).Example: F-Nr = 007003380

Page 5

132 Description2.1 Brief descriptionThe module is equipped with 12 channels which can optionally be configured as digital inputsor digital outputs.The

Page 6

2 Description14

Page 7

153 Mounting3.1 General information on installation/dismountingMounting siteAll modules have protection type IP20 and are only intended for use in fir

Page 8

3 Mounting16Minimum distances3.2 Installation/dismounting on DIN railAll modules in the system are intended for installation on a DIN rail according t

Page 9

173 MountingInstallation, using the example of a multichannel controller module 705010Example installationProcedure:(A) (A1)(A2)Step Activity1 Mount t

Page 10 - 1 Introduction

3 Mounting18Dismounting, using the example of a multichannel controller module 705010Removing the multichannel controller module from the DIN railProc

Page 11

193 Mounting3 Move the modules (B) on the right next to the multichannel controller module that is to be replaced (A) a minimum of 20 mm to the right

Page 13 - 2 Description

3 Mounting203.3 Replacing module inserts3.3.1 Input/output modulesReplacement of a module insert, using the example of a multichannel controller modul

Page 14

213 MountingRemoving the module insertMounting the module insertCAUTION!Only module inserts of the same type may be used for the replacement.Otherwise

Page 15 - 3 Mounting

3 Mounting223.4 Dimensions22.5103.66.610194.5101.517.6

Page 16

234 Electrical connection4.1 Installation notesRequirements for the personnel• Work on the modules must only be carried out to the extent described an

Page 17

4 Electrical connection24References to other information• The electromagnetic compatibility meets the standards and regulations cited in the techni-ca

Page 18

254 Electrical connection4.3.1 Display and connection elementsCAUTION!Signals to the several digital inputs must have the same ground reference.Otherw

Page 19

4 Electrical connection264.3.2 Digital input The connection depends on the configuration (input or output).4.3.3 Digital outputsThe connection depends

Page 20

274 Electrical connection4.4 Functional testThe voltage supply must be tested on completion of the electrical connection:StartupThe check described ab

Page 21

4 Electrical connection28

Page 22

295 Operation5.1 Display and connection elements(1) Status displays (LED)P = Voltage supplyS = Status1 to 12 = Digital input/output(LED is lit: Active

Page 23 - 4 Electrical connection

3Contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51.1 Available tec

Page 24

5 Operation305.2 LED displays"P" LED (Power)The LED is permanently lit in green if the module is being supplied with voltage."S" L

Page 25

315 Operation5.2.2 System states and errorsThe following table lists all the system states and errors that are indicated by the "S" LED (Sta

Page 26

5 Operation32

Page 27

336 Configuration6.1 Digital inputs/outputsThe digital input/output module has 12 channels, each of which can be configured as digitalinput or digital

Page 28

6 Configuration34Level at suppressionWhen signal suppression is active, the input signal and the inverting parameter are irrelevant.In this case, a fi

Page 29 - 5 Operation

356 Configuration6.1.1 AlarmSignal monitoring can be activated for each digital input. Setup dialogParametersEvent textSetup program: Selection of tex

Page 30

6 Configuration366.2 NV connecting listThe NV connecting list is used to link external inputs (NV_...) of the digital input/output moduleto signals fr

Page 31

376 ConfigurationReplacement valueThe replacement value is used if the relevant signal is not available (connection to base unitinterrupted or system

Page 32

6 Configuration38Programgenerator 1 toProgramgenerator 9Operating contact 1 to 16 Operating contact 1 to 16 of program channels (in the three program

Page 33 - 6 Configuration

396 ConfigurationAlarms/FaultsCAlarm/Fault System collective alarm or system fault (cen-tral processing unit and modules)CAlarm/Fault ackn. System col

Page 34

Contents44.4 Functional test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 35

6 Configuration40Multichannel controller moduleController C01ManualMode to C04ManualModeManual mode active for controller channel 1to4C01TuneActive to

Page 36

416 ConfigurationAnalog input module 4-channelAnalog inputs AI01Alarm1 to AI04Alarm1 Alarm signal 1 of analog input 1 to 4AI01Alarm2 to AI04Alarm2 Ala

Page 37

6 Configuration426.2.2 Replacement values (overview)The following table contains the replacement values with their factory settings. Replacementvalues

Page 38

437 Online parameters7.1 Calibrate / test7.1.1 Digital outputSetup dialogParametersNOTE!An active connection between the setup program and the central

Page 39

7 Online parameters447.1.2 Digital inputSetup dialogParametersParameters Selection/settings DescriptionRead out Click the "Read out" button.

Page 40

457 Online parameters7.1.3 VersionsSetup dialogThis dialog displays the module versions.

Page 41

7 Online parameters46

Page 42

478 Appendix8.1 Technical data8.1.1 Digital inputs and outputs8.1.2 Electrical dataNumber 12Digital inputsInput signal DC 0/24 V(PLC level; logical ”0

Page 43 - 7 Online parameters

8 Appendix488.1.3 Case and ambient conditions8.1.4 Approval/approval marksCase type Plastic case for DIN rail mounting in the control cabinet (indoor

Page 45

51 Introduction1.1 Available technical documentationThe documents specified below are available for the measuring, control, and automation sys-tem.1.1

Page 46

JUMO GmbH & Co. KGStreet address:Moritz-Juchheim-Straße 136039 Fulda, GermanyDelivery address:Mackenrodtstraße 1436039 Fulda, GermanyPostal addres

Page 47 - 8 Appendix

1 Introduction61.1.4 Special modules1.1.5 Operating, visualization, recording1.1.6 Power supply unitsProduct Type of documentation No. Printed PDF fil

Page 48

71 Introduction1.2 Safety information1.2.1 Warning symbols1.2.2 Note signsDANGER!This symbol indicates that personal injury caused by electrical shock

Page 49

1 Introduction81.2.3 Intended useThe modules described are intended for measuring, control, and automation tasks in an indus-trial environment, as des

Page 50

91 Introduction1.3 Acceptance of goods, storage, and transport1.3.1 Checking the delivery• Ensure that the packaging and contents are not damaged • Ch

Commentaires sur ces manuels